Professional Carbon monoxide (CO) data logger-USB with UK Sensor

AUD $425.00 Excl. GST

  • Measure and record Carbon monoxide CO
  • Single gas data logger (1 gas selection when purchasing)
  • Supports 15 types of measuring gases (flammable, toxic)
  • Real-time gas concentration and remaining battery indication
  • Imported high quality sensors (UK Sensor)
  • USB charging and continuous use for 360 hours (5 hours charge)
  • Automatic / manual sampling pump can be installed
Need Help? Call 1300 788 213 Now to Talk to an Expert!
Category:
Professional Carbon monoxide (CO) data logger-USB with UK Sensor
Professional Carbon monoxide (CO) data logger-USB with UK Sensor
Professional Carbon monoxide (CO) data logger-USB with UK Sensor
Professional Carbon monoxide (CO) data logger-USB with UK Sensor

CO2

Gas detected

Carbon Dioxide (CO2)

Measuring range

(0~5000)ppm, (0~5)%vol, (0~100)%vol

Resolution ratio

1ppm / 0.01%vol

Sensor

Infrared Sensor, Made in UK

Sensor lifetime

≥5 year

Response time

≤50s(T90)

Alarms

Audible–buzzer with ≥75dB audible

Visible–flashing red LED, ≥20m visible

Alarm point

Fully adjustable

Data logging (optional)

Continuous Data logging (9000 data at

configurable 0.1-10 minutes intervals)

Continuous working time

>16h

Working current

< 1mA ( without backlight)

Working temperature

-25℃~+55℃, short time: -40℃~+55℃

Display

Liquid crystal display (LCD)

Battery model

PL123450, 3.7V/1500mA

Charging time

4-5 hours

Dust and water resistance

IP65

Size & Weight

105*54*32mm/200g

Ex sign

ExibdⅠ

 

CO

Gas detected

Carbon Monoxide (CO)

Measuring range

(0~100)ppm,(0~1000)ppm, (0~10000)ppm

Resolution ratio

1ppm

Sensor

Electrochemical Sensor, Made in UK

Sensor lifetime

≥2 year

Response time

≤45s(T90)

Alarms

Audible–buzzer with ≥75dB audible

Visible–flashing red LED, ≥20m visible

Alarm point

Fully adjustable

Data logging (optional)

Continuous Data logging (9000 data at

configurable 0.1-10 minutes intervals)

Continuous working time

>3 months ( without backlight)

Working current

< 1mA ( without backlight)

Working temperature

-25℃~+55℃, short time: -40℃~+55℃

Display

Liquid crystal display (LCD)

Battery model

PL123450, 3.7V/1500mA

Charging time

4-5 hours

Dust and water resistance

IP65

Size & Weight

105*54*32mm/200g

Ex sign

ExibdⅠ

O2

Gas detected

Oxygen (O2)

Measuring range

(0~25)%vol, (0~30)%vol

Resolution ratio

0.1%vol

Sensor

Electrochemical Sensor, Made in UK

Sensor lifetime

≥2 year

Response time

≤35s(T90)

Alarms

Audible–buzzer with ≥75dB audible

Visible–flashing red LED, ≥20m visible

Alarm point

Fully adjustable

Data logging (optional)

Continuous Data logging (9000 data at

configurable 0.1-10 minutes intervals)

Continuous working time

>3 months ( without backlight)

Working current

< 1mA ( without backlight)

Working temperature

-25℃~+55℃, short time: -40℃~+55℃

Display

Liquid crystal display (LCD)

Battery model

PL123450, 3.7V/1500mA

Charging time

4-5 hours

Dust and water resistance

IP65

Size & Weight

105*54*32mm/200g

Ex sign

ExibdⅠ

 

O2 100%

Gas detected

Oxygen (O2)

Measuring range

(0~100)%vol

Resolution ratio

1%vol

Sensor

Electrochemical Sensor, Made in UK

Sensor lifetime

≥2 year

Response time

≤35s(T90)

Alarms

Audible–buzzer with ≥75dB audible

Visible–flashing red LED, ≥20m visible

Alarm point

Fully adjustable

Data logging (optional)

Continuous Data logging (9000 data at

configurable 0.1-10 minutes intervals)

Continuous working time

>3 months ( without backlight)

Working current

< 1mA ( without backlight)

Working temperature

-25℃~+55℃, short time: -40℃~+55℃

Display

Liquid crystal display (LCD)

Battery model

PL123450, 3.7V/1500mA

Charging time

4-5 hours

Dust and water resistance

IP65

Size & Weight

105*54*32mm/200g

Ex sign

ExibdⅠ

 

H2S

Gas detected

Hydrogen Sulphide (H2S)

Measuring range

(0~100)ppm,(0~1000)ppm, (0-2000)ppm

Resolution ratio

1ppm

Sensor

Electrochemical Sensor, Made in UK

Sensor lifetime

≥2 year

Response time

≤45s(T90)

Alarms

Audible–buzzer with ≥75dB audible

Visible–flashing red LED, ≥20m visible

Alarm point

Fully adjustable

Data logging (optional)

Continuous Data logging (9000 data at

configurable 0.1-10 minutes intervals)

Continuous working time

>3 months ( without backlight)

Working current

< 1mA ( without backlight)

Working temperature

-25℃~+55℃, short time: -40℃~+55℃

Display

Liquid crystal display (LCD)

Battery model

PL123450, 3.7V/1500mA

Charging time

4-5 hours

Dust and water resistance

IP65

Size & Weight

105*54*32mm/200g

Ex sign

ExibdⅠ

H2

Gas detected

Hydrogen (H2)

Measuring range

(0~1000)ppm

Resolution ratio

1ppm

Sensor

Electrochemical Sensor, Made in UK

Sensor lifetime

≥2 year

Response time

≤45s(T90)

Alarms

Audible–buzzer with ≥75dB audible

Visible–flashing red LED, ≥20m visible

Alarm point

Fully adjustable

Data logging (optional)

Continuous Data logging (9000 data at

configurable 0.1-10 minutes intervals)

Continuous working time

>3 months ( without backlight)

Working current

< 1mA ( without backlight)

Working temperature

-25℃~+55℃, short time: -40℃~+55℃

Display

Liquid crystal display (LCD)

Battery model

PL123450, 3.7V/1500mA

Charging time

4-5 hours

Dust and water resistance

IP65

Size & Weight

105*54*32mm/200g

Ex sign

ExibdⅠ

 

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Model No.
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Compare
Wishlist 0
Open wishlist page Continue shopping